3.2.9 ow<cr>:Set./Read photo finish trigger length
This command sets the duration of the photo finish signal. Some frame
capture devices will take more than one picture if their triggering signal is too long.
The number in this command is the number of milliseconds the trigger signal will
last.
ComputerFinish Line
Sends
ow<cr> Read current value of trigger (in milliseconds)
Description
ow20<cr> Set photo finish trigger length;
allowable range is 1 to 255 milliseconds.
Finish Line Computer
Returns
020<cr><lf> Value set for photo finish trigger length is returned.
Description
<cr><lf> Carriage return sent when setting a new value.
?<cr><lf> Invalid command.
3.2.10 ox<cr>:Set the Champ Timer Finish Line to DTX000 mode
This command sets the Champ Timer Finish Line into DTX000 mode. The
Champ Timer will use the DTX000 format to reset when a <SPACE> character is
received and to send the response string when the last car finishes. The response
string will be in the following format:
1 1.1234 2 2.2345 3 3.3456 and so on.
The placement is determined by the order in which they are returned. For example,
2 0.8984 1 1.2326 4 1.3283 3 1.5339
ComputerFinish Line
Sends
ox1<cr> Go into DTX000 format mode.
Description
ox0<cr> Return to Champ Timer lower and upper case
mode.
Finish Line Computer
Returns
No response is sent. Timer is reset to new mode.
Description
?<cr><lf> Invalid command.